Path: Top Member rina@tf.itb.ac.id

PERANCANGAN DAN IMPLEMENTASI SAFETY INSTRUMENTED SYSTEM PADA MINIATUR PASTEURISASI MENGGUNAKAN PROGRAMMABLE LOGIC CONTROLLER

DESIGN AND IMPLEMENTATION OF SAFETY INSTRUMENTED SYSTEM FOR MINIATURE OF PASTEURIZATION USING PROGRAMMABLE LOGIC CONTROLLER

Undergraduate Theses from JBPTITBTF / 2017-07-08 12:36:37
Oleh : Maesy NIM 13313047 & Nina Nugraheni NIM 13313056
Dibuat : 2017-07-05, dengan 10 file

Keyword : Safety Instrumented System, miniatur pasteurisasi, PLC, Hazard and Operability Study, Risk Reduction Factor

Keselamatan kerja merupakan faktor yang tidak dapat diabaikan dalam industri proses. Salah satu lapisan proteksi yang dapat menjamin keselamatan kerja pada suatu industri adalah Safety Instrumented System (SIS). Perancangan SIS yang diatur dalam standar ANSI/ISA No. 84.00.01-2004 meliputi tahap analisis, tahap implementasi, tahap operasi, dan tahap verifikasi. Miniatur pasteurisasi di Laboratorium Manajemen Sistem Instrumentasi dan Kontrol akan dijadikan objek pembelajaran untuk memahami konsep tingkat safety serta perancangan SIS. Analisis risiko dilakukan dengan menggunakan metode Hazard and Operability Study dan Risk Matrix, dan ditentukan nilai Safety Integrity Level (SIL) untuk miniatur pasteurisasi dengan metode Risk Graph. Perancangan SIS dilakukan dengan membuat kombinasi-kombinasi dari delapan konfigurasi sistem. Perhitungan dengan Fault Tree Analysis digunakan untuk mengetahui besarnya Probability of Failure on Demand average (PFDavg) yang diperlukan dalam penentuan SIL dari tiap kombinasi SIS. Rancangan terbaik dipilih berdasarkan analisis Analytical Hierarchy Process (AHP) dengan mempertimbangkan nilai PFDavg dan biaya. Penambahan SIS pada miniatur pasteurisasi menghasilkan peningkatan nilai Risk Reduction Factor (RRF) keseluruhan sistem sebesar 83 kali dibandingkan dengan sebelum penambahan SIS. Hasil dari perancangan tersebut kemudian disimulasikan dengan menggunakan PLC Allen Bradley RS Logix 5000.

Deskripsi Alternatif :

Safety is a factor that can not be ignored in the process industry. One layer of protection to ensure safety in the industry is safety instrumented system (SIS). The design of SIS in the standard ANSI / ISA No. 84.00.01-2004 includes the analysis phase, implementation phase, operation phase, and the verification phase. Miniature of pasteurization at the Laboratory of Instrumentation Management and Control Systems used as a medium of learning to understand the concept of the level of safety and the design of SIS. Risk analysis using the Hazard and Operability Study and Risk Matrix is required to define Safety Integrity Level (SIL) of miniplant of pasteurization. Design of SIS done by making combinations of system configurations. Fault Tree Analysis is used to determine the Probability of Failure on Demand average (PFDavg) required in determining the SIL of each combination of SIS. The addition of SIS on miniature of pasteurization make the Risk Reduction factor (RRF) of the whole system increases for about 83 times compared by before the addition of SIS. The results of the design is then simulated using PLC Allen Bradley RS Logix 5000.

Beri Komentar ?#(0) | Bookmark

PropertiNilai Properti
ID PublisherJBPTITBTF
Organisasi
Nama KontakRina
AlamatPerpustakaan Departemen Teknik Fisika
KotaBandung
DaerahJawa Barat
NegaraIndonesia
Telepon
Fax
E-mail Administratoradmin@tf.itb.ac.id
E-mail CKOckolib@tf.itb.ac.id

Print ...

Kontributor...

  • Pembimbing: 1. Dr. Ir. Sutanto Hadisupadmo, M.T. 2. Augie Widyotriatmo, S.T., M.T., Ph.D., Editor: Rina Kania

Download...